槽式電纜橋架
槽(cao)式(shi)(shi)電(dian)(dian)(dian)纜(lan)橋架橋架是一種全(quan)封閉型(xing)電(dian)(dian)(dian)纜(lan)橋架,它(ta)(ta)最適用(yong)于敷設計(ji)算(suan)機電(dian)(dian)(dian)纜(lan)、通信電(dian)(dian)(dian)纜(lan)、熱(re)電(dian)(dian)(dian)偶(ou)電(dian)(dian)(dian)纜(lan)及其(qi)(qi)(qi)它(ta)(ta)高靈(ling)敏系統(tong)的(de)控制電(dian)(dian)(dian)纜(lan)等,它(ta)(ta)對控制電(dian)(dian)(dian)纜(lan)的(de)屏(ping)蔽干擾和重腐(fu)蝕環境中(zhong)電(dian)(dian)(dian)纜(lan)的(de)防護都有(you)較好效果。而且槽(cao)式(shi)(shi)電(dian)(dian)(dian)纜(lan)橋架其(qi)(qi)(qi)材(cai)質有(you)不銹鋼、鋁合金、鋼質三種。槽(cao)式(shi)(shi)玻(bo)璃(li)鋼橋架的(de)護罩隨槽(cao)體(ti)配套供貨,其(qi)(qi)(qi)它(ta)(ta)配件與梯級式(shi)(shi)、托盤式(shi)(shi)橋架通用(yong)。表面(mian)處理(li)分(fen)為鍍鋅、防火、靜電(dian)(dian)(dian)噴(pen)塑(su)、熱(re)浸鋅等,在重腐(fu)蝕環境中(zhong)可特(te)殊防腐(fu)處理(li)。
槽式電纜橋架可以用于全封閉型電纜敷設。它最適合用于敷設計算機電纜、通信電纜、熱電偶電纜及其它高靈敏系統的控制電纜。它對控制電纜的屏蔽干擾和重腐蝕環境中電纜的防護都有較好效果。
1)槽式電(dian)纜橋架(jia)及其支吊架(jia)使用在有腐蝕性環境中,應采用耐腐蝕的剛性材料制造,或(huo)采取防腐蝕處理,防腐蝕處理方式應滿(man)足工(gong)程(cheng)環境和(he)耐久(jiu)性的要(yao)求(qiu)。
2)電纜橋架在有防火要求的區段內,可在電纜梯架、托盤內添加具有耐火或難燃性能的板、網等材料構成封閉或半封閉式結構,并采取在橋架及其支吊架表面涂刷防火涂層等措施,其整體耐火性能應滿足國家有關規范或標準的要求。
3)在工程防火要求較高的場所,不宜采用鋁合金電纜橋架。
4)槽式電纜(lan)橋架寬度和(he)高度的選擇(ze)應符合填充率(lv)的要求,電纜(lan)的梯(ti)架和(he)托盤內的填充率(lv)在一般(ban)情況(kuang)下(xia),電力電纜(lan)可(ke)取(qu)40%~50%,控制電纜(lan)可(ke)取(qu)50%~70%,且宜預留10%~25%工(gong)程發展裕量。
5)在選(xuan)擇電(dian)纜(lan)橋架的荷(he)(he)(he)載等級時,電(dian)纜(lan)橋架的工作均(jun)布荷(he)(he)(he)載不應(ying)大于(yu)所選(xuan)電(dian)纜(lan)橋架荷(he)(he)(he)載等級的額定均(jun)布荷(he)(he)(he)載,如果電(dian)纜(lan)橋架的支吊架的實際跨距不等于(yu)2m時,則工作均(jun)布荷(he)(he)(he)載應(ying)滿足要求。
6)各種組件及支吊架在滿足相應荷載的條件下,其規格尺寸應與托盤、梯架的直線段、彎通系列相匹配。
7)在選擇(ze)槽式電纜橋(qiao)(qiao)架的彎通或引(yin)上、引(yin)下裝置時,不應(ying)小于電纜橋(qiao)(qiao)架內電纜最小允(yun)許彎曲半徑。
8)對于跨(kua)距(ju)大于6m的(de)鋼(gang)制電纜橋(qiao)架(jia)和跨(kua)距(ju)大于2m 或承載(zai)要(yao)求大于荷載(zai)等(deng)級D級的(de)鋁合金電纜橋(qiao)架(jia),應按工程條件進行強度、剛度及穩定性的(de)計算或試驗驗證。
9)幾組電纜橋架(jia)在同一高度平行(xing)敷設時,各(ge)相鄰電纜橋架(jia)之間(jian)應考慮維(wei)護、檢修距離。
10)槽(cao)式電(dian)纜(lan)橋架(jia)的(de)直通單件標準長度可(ke)為2、3、4、6m